项目(Item) 数据(Data)
认证(APPROVAL)  认证查询链接  认证查询链接
测试标准(Test standard) IEC/ EN60998-1:2004 / UL1059
产品间距(Pitch) [mm] 5.0
极数(Poles) 01-XXP
EN60998测试数据(EN60998 Test data) VDE certificate NO. 40030722
额定电压(Rated insulation voltage) [V] 250
额定电流(Rated current) [A] 15
额定连接容量(Rated connection capacity)(solid/stranded) [mm²] 0.2-1.5
过压类别/污染等级/绝缘材料组别
(Surge voltage category/pollution degree/material group)
III/2/I
额定冲击电压(Rated impulse voltage) [KV] 2.5
额定扭矩(Rated torque) [N.m] /
UL1059测试数据(UL1059 Test data) UL File Number E228872
应用组别(Use group) B C D
电压(Voltage) [V] 300 / /
电流(Current) [A] 8 / /
额定连接容量(Rated connection capacity) (solid/stranded) [AWG] 26-16
额定扭矩(Rated torque) [Lb. in] /
常用数据(General data) /
螺丝(Screw) /
阻燃等级(Inflammability class)UL94 V0
环境温度(Ambient temperature) [℃] -40~+105
相对湿度(Relative humidity) 5%-95%
抽样检验标准(Inspection standard) MIL-STD-105E II
允收水准(AQL) 0.65
保质期(Warranty) 12 months
材质和电镀 /
绝缘材质(Housing) PA66
弹片(Spring) Stainless不锈钢
焊脚(Pin header) Copper alloy,Sn plated铜合金,镀锡
接线方法 (Wire connecting)
推荐剥线长度8-9mm; Recommended stripping length 8-9mm;
1.)单股硬导线,剥好对应长度的导线后,下压按钮同时将单线接入;
For solid wire,  stripping wire to the appointed length ,press button and insert the wire.
2.)多股柔性导线,剥好对应长度的导线后,可以直接连接或者配套使用对应标准规格的冷压端头,下压按钮同时将线接入;
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.