项     目 (Item) 数     据 (Data)
认证(APPROVAL) 认证查询连接
测试标准(Test standard) IEC60947-7-4/   UL1059
产品间距(Pitch)                                      [mm] 20.00
极数(Poles) 01-12P
IEC60947-7-4测试数据( IEC60947-7-4 Test data) /
额定电压(Rated voltage)                              [V] 1000
额定电流(Rated current)                              [A] 76
额定连接容量(Rated connection   capacity)(solid/stranded) [mm2] 0.2-16
过压类别/污染等级/绝缘材料组别

(Surge   voltage category/pollution degree/material group)

III/2/I
额定冲击电压(Rated impulse   voltage)                    [KV] 12.0
额定扭矩(Rated torque)                               [N.m] /
UL1059测试数据(UL1059Test data) UL   File Number E228872
应用组别(Use group) B C D
额定电压(Rated voltage)                              [V] 660 660 600
额定电流(Rated current)                              [A] 66 66 5
额定连接容量(Rated connection   capacity) (solid/stranded) [AWG] 24-4
额定扭矩(Rated torque)                              [Lb. in] /
通用数据(General data) /
螺丝(Screw) /
阻燃等级(Inflammability   class)UL94 V0
环境温度(Ambient   temperature)                        [℃] -40~+105
相对湿度(Relative humidity) 5%-95%
抽样检验标准(Inspection standard) MIL-STD-105E   II
允收水准(AQL) 0.65
保质期(Warranty) 12   months
材质和电镀(Material and plating) /
绝缘材质(Housing) PA66
弹片(Spring) Stainless不锈钢
焊脚(Pin header) Copper alloy,Sn plated铜合金,镀锡
接线方法(Wire connecting)
推荐剥线长度12-13mm; Recommended stripping   length 12-13mm;
1.)单股硬导线,剥好对应长度的导线后,下压弹片同时将单线接入;

For   solid wire,  stripping wire to the   appointed length ,press spring and insert the wire.

2.)多股柔性导线,剥好对应长度的导线后,可以直接连接或者配套使用对应标准规格的冷压端

头,下压弹片同时将线接入;

For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.

 